Trol Counter Specs:
3.2" (81.5mm) wide, 2.55" (65mm) high, 1.25" (32mm) deep
polycarbonate overlay over .058" thick aluminum face plate
.06" thick neoprene gasket seals to NEMA type 12 protection
supplied data cable is 30" (763mm) long
Display
2 line x 12 character super twist LCD, 40 degree viewing angle
character size is .25" (6.20mm) high, by .13" (3.2mm) wide
operating temperature range 0 to 50 deg. C. (32 to 120 deg. F.)
storage temperature range -20 to 70 deg. C. (-4 to 158 deg. F.)
Power Requirements
Power is supplied by the T6+ MCU via data cable, 5 volts max.
Performance
Each counter can be operated by any page, any number of times counting range is 0 to 59,999
Max. count speed is 100cps, which is limited MCU line execution
15 individual messages, containing 24 characters each
counter settings and messages are stored internally via nonvolatile eeprom which does not require battery backup.
OEM considerations:
Custom cable lengths for the RCP are available. Multiple RCP units can be "cloned" using a Program Transfer Module (part number PTM-02). This eliminates the need to setup each RCP individually. It will also store a copy of the RCP's program for backup.