Trol T6 Controller

MCU-04-115
Only
Add to cart
  • Description
  • More

Trol T6 Controller 115VAC

Power Requirements

115VAC @ .02A, 50/60Hz w/1000v magnetic isolation

Outputs

4 normally open relay contacts unprotected, no leakage current

5Amps @ 230VAC (resistive load), 250 VA (inductive load)

Response time: 10ms operate / 5ms release

Rated life: 5 million (mech) / 200,000 @ 3A (resistive load)

Inputs

6 self powered, 12-14 VDC @ 10ma. w/ 1000v optical isolation

Maximum leakage of input device: 0.5ma

Response time: all are factory set at 10ms, the user may change

any input to between 0 to 255ms using the Setup Menu

Physical

Size 2.9" (75mm) x 2.2" (55mm) x 4.3" (110 mm)

Mounting DIN rail or panel (with two #6 screws)

Weight 10 oz. (284 grams)

Temp 0 - 140° F, 90% r. humidity (no condensation)

Origin Designed and assembled in the USA.

Contact [email protected] for additional information