C201B CIP Safety Control Units by Inxpect

Internal view of a digital device's circuit board with multiple chips and connectors.

C201B-C

CIP SafetyTM, Ethernet and digital I/O

C201B-C provides a safety communication based on CIP SafetyTM on EtherNet/IPTM. The Inxpect Safety Application allows the configuration of sensitivity levels, safety functions, size of detection fields, and the functionality of the I/O ports of the control unit.
Safety fieldbus
CIP SafetyTM over EtherNet/IPTM.
Secure Ethernet
Remote configuration and management protected by industry standard cyber security protocols.
USB
Local configuration option.
Digital inputs
The system has two TYPE3 dual channel inputs. Alternatively, the four channels can be used as single channel digital inputs (category 2). Supporting the following functions:
• muting signal
• emergency stop signal
• restart signal
Four Output Signal Switching Devices
As safety outputs:  two dual-channel safety OSSDs.
As auxiliary outputs:  four auxiliary outputs, which can be configured as signal restart feedback, fault, muting status.
Dynamic setting of detection fields
The connection allows to have up to 32 configurations switchable in real time.
SD backup, SD restore
Configurations and login credentials can be saved and restored via microSD card.

Diagram illustrating safety fields, dynamic setting of detection fields, and secure Ethernet configuration.
Diagram illustrating safety outputs in a system with feedback and fault detection.
Technical specifications for a 4-zone digital switching device with USB and HDMI ports.
Diagram showing dimensions of a rectangular object with labeled measurements.