Trol Analog I/O Units by Trol Systems

Air-Oil Systems

Manufacturer: Trol Systems

Part No. 5/4-80A-115, 5/4-90A-115, 5/4-80A-1224, 5/4-90A-1224
Power Requirements
Models xx-115: 115VAC + 10% @ .04A, 50 or 60 Hz
Models xx-1224: 12 to 24VDC @ .30A
Outputs
4 solid state NPN open collector, 28v zener protected
500 ma. intermittent load, 300 ma. continuous
24vdc (max) operating voltage
Duty cycle programmable in 1% increments
PWM frequency of 1khz
Inputs
5, capable of reading a positive 0 to10 volt signal
20k input impedance, pulled down (bias toward 0v)
Programmed in 0.040 volt resolution (total of 255 steps)
User selectable polling speed 10 to 2550ms (see page 14)
Input indicator light intensity reflects the input's voltage
Auxiliary Input power supply
10.0vdc @ 100ma., thermal overload protected
Physical Size 2.9" (75mm) x 2.2" (55mm) x 4.3" (110 mm)
Mounting DIN rail or panel (with two #6 screws)
Weight 14 oz. (400 grams)
Temp -20 to 140° F, 90% r. humidity (non cond.)
Origin Designed and assembled in the USA.
Performance
Timing Output + 1 ms repeatability
Communication to/from the MCU within 850 us (typ) / line
Data Port Dual IIc bus @ 100khz