controllers

Controllers

Trol Systems are a complete machine control system that is ultra easy to program and low cost too! Absolutely no training or programming experience is required.

 

Only $299 for the Complete Start-Up Kit!  Our prices are the best anywhere. 

The Trol T6 is unlike any other controller in the market.  Basic verbal commands are used instead of complicated ladder and machine programs so you can program your device easily and be up and running your controlled device in minutes instead of hours

Trol T6 Start Up Kit

Trol T6 Startup
From
Add to cart

The T6 is programed by choosing words from a menu that form sentences of a page. Naturally, you write program in the same order as the machine operates. This allows the T6 to use just a few simple functions, since program execution is already organized. No electrical, computer or mathematical symbols are used. Even someone who didn't write the program of a T6 can still understand how it will operate!

Choose your programming method, Voltage, Pocket Programmer or Windows PC Link

This kit gives you everything you need to control a
small 115vac* machine. Open the box and start
writing your program in just minutes! Add I/O
sections or a remote panel as the needs of your machine grow. This kit contains:
  • T6+ Controller (MCU-02-115) 115vac 50/60Hz
  • Pocket Programmer (PGM-02)
  • Owner's Manual
  • Getting Started Manual
  • Optional Equipment booklet
  • Materials for example programs
Only
Add to cart
Trol T6 Controller 115VAC

Power Requirements

115VAC @ .02A, 50/60Hz w/1000v magnetic isolation

Outputs

4 normally open relay contacts unprotected, no leakage current

5Amps @ 230VAC (resistive load), 250 VA (inductive load)

Response time: 10ms operate / 5ms release

Rated life: 5 million (mech) / 200,000 @ 3A (resistive load)

Inputs

6 self powered, 12-14 VDC @ 10ma. w/ 1000v optical isolation

Maximum leakage of input device: 0.5ma

Response time: all are factory set at 10ms, the user may change

any input to between 0 to 255ms using the Setup Menu

Physical

Size 2.9" (75mm) x 2.2" (55mm) x 4.3" (110 mm)

Mounting DIN rail or panel (with two #6 screws)

Weight 10 oz. (284 grams)

Temp 0 - 140° F, 90% r. humidity (no condensation)

Origin Designed and assembled in the USA.

Only
Add to cart
Trol T6 Controller 24 VDC

Power Requirements

12 to 24 VDC @ .3A (30 volts absolute maximum)

Outputs

4 normally open relay contacts unprotected, no leakage current

5Amps @ 230VAC (resistive load), 250 VA (inductive load)

Response time: 10ms operate / 5ms release

Rated life: 5 million (mech) / 200,000 @ 3A (resistive load)

Inputs

6 self powered, 12 VDC @ 10ma. w/1000v optical isolation

Maximum leakage of input device: 0.5ma

Response time: all are factory set at 10ms, the user may change any input to between 0 to 255ms using the Setup Menu

Physical

Size      2.9" (75mm) x 2.2" (55mm) x 4.3" (110 mm)

Mounting      DIN rail or panel (with two #6 screws)

Weight      8 oz. (227 grams)

Temp      0 to 140° F, 90% r. humidity (no condensation)

Origin      Designed and assembled in the USA.

Now Only
Add to cart
Expansion modules for TROL
Trol I/O Expansion Module Power Requirements

115VAC  .02A, 50/60Hz w/1000v magnetic isolation (I/O blocks are also available in 230vac or 12-24 vdc)
Outputs
4 normally open relay contacts unprotected, no leakage current 5Amps 230VAC (resistive load), 250 VA (inductive load)
Response time:
10ms operate / 5ms release
Rated life: 5 million (mech) / 200,000  3A (resistive load)
Inputs
6 self powered, 12-14 VDC  10ma. w/ 1000v optical isolation Maximum leakage of input device: 0.5ma Response time: all are factory set at 10ms, the user may change any input to between 0 to 255ms using the Setup
Physical
Size 2.9 (75mm) x 2.2(55mm) x 4.3 (110 mm)
Mounting DIN rail or panel
Weight 10 oz. (284 grams)
Temp 0 - 140 F, (no condensation)
Origin Designed and assembled in the USA.
Now Only
Add to cart
Trol counter panel

Trol Counter Specs:

3.2" (81.5mm) wide, 2.55" (65mm) high, 1.25" (32mm) deep

polycarbonate overlay over .058" thick aluminum face plate

.06" thick neoprene gasket seals to NEMA type 12 protection

supplied data cable is 30" (763mm) long

Display

2 line x 12 character super twist LCD, 40 degree viewing angle

character size is .25" (6.20mm) high, by .13" (3.2mm) wide

operating temperature range 0 to 50 deg. C. (32 to 120 deg. F.)

storage temperature range -20 to 70 deg. C. (-4 to 158 deg. F.)

Power Requirements

Power is supplied by the T6+ MCU via data cable, 5 volts max.

Performance

Each counter can be operated by any page, any number of times counting range is 0 to 59,999

Max. count speed is 100cps, which is limited MCU line execution

15 individual messages, containing 24 characters each

counter settings and messages are stored internally via nonvolatile eeprom which does not require battery backup.

OEM considerations:

Custom cable lengths for the RCP are available. Multiple RCP units can be "cloned" using a Program Transfer Module (part number PTM-02). This eliminates the need to setup each RCP individually. It will also store a copy of the RCP's program for backup.

Now Only
Add to cart

Trol Timer Panel

Trol Timer Specs:

3.2" (81.5mm) wide, 2.55" (65mm) high, 1.25" (32mm) deep

polycarbonate overlay over .058" thick aluminum face plate

.06" thick neoprene gasket seals to NEMA type 12 protection

supplied data cable is 30" (763mm) long

Display

2 line x 12 character super twist LCD, 40 degree viewing angle character size is .25" (6.20mm) high, by .13" (3.2mm) wide

operating temperature range 0 to 50 deg. C. (32 to 120 deg. F.)

storage temperature range -20 to 70 deg. C. (-4 to 158 deg. F.)

Power Requirements

Power is supplied by the T6+ MCU via data cable, 5 volts maximum

Performance

Each timer can be operated by any page, any number of times timing range is .01 to 49,999.90 seconds in 10ms resolution

Timing accuracy is + 3ms repeatability

15 individual messages, containing 24 characters each

Timer settings and messages are stored internally via nonvolatile eeprom which does not require battery backup.

OEM considerations

Custom cable lengths for the RTP are available. Multiple RTP units can be "cloned" using a Program Transfer Module (part number PTM-02). This eliminates the need to setup each RTP individually. It will also store a copy of the RTP's program for backup.

Add to cart
DIN RAIL SECTIONS
Pre-cut aluminum DIN rail sections allow easy mounting of the T6 system. Use end blocks to prevent units from "walking" due to vibration, especially when rails are mounted vertically.
Now Only
Add to cart
Converter Block
A Trol converter block is used to allow the T6 inputs (sinking configuration), to interface with devices that send out 115vac power. Units are 1" square plastic housing with two mounting flanges.
Only
Add to cart
 

USB-Serial Adapter

Includes Cable, Software and User Guide

If your computer does not have a serial Com port, this is used to convert a USB port to an RS-232 serial port. 
Will work with CIM-03 and also the MCU-04